Piping Insulation Evaluation Device

  • 극저온 장비

Customer :

Pusan National University
  • Purpose : To evaluate the insulation performance of Piping
  • Technical Features : 2 Side Guard Chamber & Test Pipe

   – Test Pipe Size          : 3 inch (OD 88.9mm) x 2000L (Pipe)

   – Guard Chamber Volume : 53 liters (1 Guard Chamber)

   – Fluid          : LN2, LHe

   – Design Pressure          :  10 barg

   – Operating Temperature   : 269 ~ 40 °C

   – DAQ(Data Acquisition)    : Temperature, Pressure, Flow rate, Level(DP), Vacuum rate

Piping Insulation Evaluation Device

  • 극저온 장비

Customer : 

Pusan National University
  • Purpose : To evaluate the insulation performance of Piping
  • Technical Features : 2 Side Guard Chamber & Test Pipe

   – Test Pipe Size          : 3 inch (OD 88.9mm) x 2000L (Pipe)

   – Guard Chamber Volume : 53 liters (1 Guard Chamber)

   – Fluid          : LN2, LHe

   – Design Pressure          :  10 barg

   – Operating Temperature   : 269 ~ 40 °C

   – DAQ(Data Acquisition)    : Temperature, Pressure, Flow rate, Level(DP), Vacuum rate