Cooling System for HTS Quadrupole Magnet
- 극저온 냉각 설비
Customer :
● Purpose : to cooldown the seven HTS Quadrupole Magnets
● Technical Features : consist of Distribution Box,
Helium Reservoir and Multi Transfer Line
– Design Pressure : 12 kgf/cm2
– Operation Temperature : ~ 35 K
– Cooling Capacity : 2000 W @ 35 K
– Cold Helium Circulation : ~ 70 g/s
▲ Distribution Box
– Diameter : 1300 mm
– Length : 3122 mm
– Height : 2365 mm
▲ Transfer Line
– 14 process lines in one vacuum jacket
– Length : 60 m
Cooling System for HTS Quadrupole Magnet
- 극저온 냉각 설비
Customer :
● Purpose : to cooldown the seven HTS Quadrupole Magnets
● Technical Features : consist of Distribution Box,
Helium Reservoir and Multi Transfer Line
– Design Pressure : 12 kgf/cm2
– Operation Temperature : ~ 35 K
– Cooling Capacity : 2000 W @ 35 K
– Cold Helium Circulation : ~ 70 g/s
▲ Distribution Box
– Diameter : 1300 mm
– Length : 3122 mm
– Height : 2365 mm
▲ Transfer Line
– 14 process lines in one vacuum jacket
– Length : 60 m